shape

Dry Block Heater

A large selection of heating blocks for different reaction vessels and plates makes the IKA dry block heaters flexible laboratory companions. Depending on the design of the block thermostat, up to four precision heating blocks can be temperature controlled with one device.

Request a Quote

Dry Block Heater 1

Digital block heater for one aluminum block provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations.

  • Stepless adjustable temperature up to 120 °C
  • Timer: Countdown, adjustable from 1 min to 99h 59min
  • Counter: Display of heating time
  • Highly versatile with a large number of blocks
  • Error code display
  • Fixed safety circuit
  • Acoustic signal at end of test



Scope of delivery

  • Dry Block Heater 1
  • Block remove tool
  • PT 1000.60 Temperature sensor, stainless steel

 

IKA Dry Block Heater Dry Block Heater 1

 

 

 

 

 

 

Dry Block Heater 2

Digital block heater for two aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations.

  • Stepless adjustable temperature up to 120 °C
  • Timer: Countdown, adjustable from 1 min to 99h 59min
  • Counter: Display of heating time
  • Highly versatile with a large number of blocks
  • Error code display
  • Fixed safety circuit
  • Acoustic signal at end of test



Scope of delivery

  • Dry Block Heater 2
  • Block remove tool
  • PT 1000.60 Temperature sensor, stainless steel

 

IKA Dry Block Heater Dry Block Heater 2

 

 

 

 

 

 

Dry Block Heater 3

Digital block heater for three aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media test, coagulation test, blood-urea-nitrogen determination and in situ hybridizations.

  • Stepless adjustable temperature up to 120 °C
  • Timer: Countdown, adjustable from 1 min to 99h 59min
  • Counter: Display of heating time
  • Highly versatile with a large number of blocks
  • Error code display
  • Fixed safety circuit
  • Acoustic signal at end of test



Scope of delivery

  • Dry Block Heater 3
  • Block remove tool
  • PT 1000.60 Temperature sensor, stainless steel

 

 

IKA Dry Block Heater Dry Block Heater 3

 

 

 

 

 

 

Dry Block Heater 4

Digital block heater for four aluminum blocks provides precise temperature control in small vessels. Included PT-1000 temperature sensor allows temperature control directly in the sample vessel. It is used with PCR tubes, PCR strips, Greiner tubes, microplates and cuvettes. The block heater is ideal for melting and boiling point determination, enzyme reactions, incubation and activation of cultures, immunoassays, DNA denaturation, culture media tests, coagulation tests, blood-urea-nitrogen determinations and in situ hybridizations.

  • Stepless adjustable temperature up to 120 °C
  • Timer: Countdown, adjustable from 1 min to 99h 59 min
  • Counter: Display of heating time
  • Highly versatile with a large number of blocks
  • Error code display
  • Fixed safety circuit
  • Acoustic signal at end of test



Scope of delivery

  • Dry Block Heater 4
  • Block remove tool
  • PT 1000.60 Temperature sensor, stainless steel

 

IKA Dry Block Heater Dry Block Heater 4

shape