The RUMED® Safety T-Line offers a variable program of cold/heat and environmental test cabinets with explosion-proof test chambers for zone 1. Choose from 5 sizes and a multitude of options.

The units of the Safety T-Line are suitable for safe storage of explosive materials, such as aerosols, or for tests with adhesives or paint – even if the storage tests might occasionally or temporary cause an explosive atmosphere. Development of a permanent or long-term explosive atmosphere must be avoided by means of the option Technical Ventilation. The units are suitable for storage of material of the temperature classes T1, T2 and T3 of explosion group IIA, IIB and IIC. All appliances of the T-Line have successfully passed a demanding type examination according to annex III of the ATEX 2014/34/EU. RUMED® is a manufacturer of explosion-proof equipment being certified according to ISO 80079-34. This involves periodical inspections (audits) by a notified authority and a highly effective quality management system of worldwide importance.

Optionally available with extension of the temperature range to -20 °C/+80 °C, humidification and dehumidification and further options. Configure your test equipment, which is the most suitable for your requirements.

Request a Quote

General view of the most important advantages:

  • Test room Ex Logo II 2/- G Ex dbeb h [ib] ibmb IIB+H2 T3 Gb
  • 5 Test room sizes: 320 l to 1.640 l
  • Test room and external housing of solvent-resistant stainless steel
  • Recirculating air fan for good temperature distribution in space
  • Intuitive handling by means of the Control2015 touch
  • Temperature ranges from -20 °C to +80 °C
  • Humidification and dehumidification possible
  • Possibility of calibration and validation
  • Robust and extremely durable

Technical Data

Type T320 T500 T820 T1000 T1640
explosion-proof Ex LogoII 2/- G Ex dbeb h [ib] ibmb IIB+H2 T3 Gb
Volume (l) 320 500 820 1000 1640
Minimum temperature 0 °C 0 °C 0 °C 0 °C 0 °C
Maximum temperature +35 °C +35 °C +35 °C +35 °C +35 °C
Temperature deviation in time ( °C) ±0,5 °C ±0,5 °C ±0,5 °C ±0,5 °C ±0,5 °C
Height (mm) 990 1500 1500 1500 1500
Width (mm) 610 610 610 2x610 2x610
Depth (mm) 585 585 935 585 935
Number of shelves (standard delivery scope) 3 4 4 8 8
Maximum load per shelf (kg) 25 25 25 25 25
Unit
Height (mm) 1600  2105 2105 2105 2105
Width (mm) 760 760 760 1520 1520
Depth (mm) 900  900 1250 900 1250
Electric connection (V/Hz) 230/50 230/50 230/50 230/50 230/50
Options
Additional shelf T0320-01 T0500-01 T0820-01 T1000-01 T1640-01
Additional shelf, reinforced (maximum load per shelf 50 kg) T0320-02 T0500-02 T0820-02 T1000-02 T1640-02
Glazed panel door, no pane heating T0320-03 T0500-03 T0820-03 T1000-03 T1640-03
Extension of temperature range down to -20 °C T0320-04 T0500-04 T0820-04 T1000-04 T1640-04
Extension of temperature range up to +80 °C* T0500-05 T0820-05 T1000-05 T1640-05
Speed rate in temperature change 1 °C/min (0 °C to +35°C) T0320-06 T0500-06 T0820-06 T1000-06 T1640-06
Speed rate in temperature change 1 °C/min (-20 °C to +80 °C) T0320-07 T0500-07 T0820-07 T1000-07 T1640-07
Ultrasonic humidification + dehumidification** T0320-20 T0500-20 T0820-20 T1000-20 T1640-20

*Electric connection is then 400 V/230 V/50 Hz, unit depth is then + 225 mm
**Unit depth is then +160 mm, removable for transportation

 

Option

  • Tubular port

A 45 mm duct in the side panel allows insertion of measuring lines and hoses into the test room. Delivery including cover.

Order No.: T9930-01

 

 

 

  • Closing Plug

Gas-tight closing plug, matching to the tubular port. The gasket system with a flexibility in the range of 4 mm to 23 mm is based on a rubber module with removable skins and can be adapted to the cables, tubes etc. in different sizes.

Order No.: T9930-02

 
 
  • Steering Rollers

Mobile version of the test cabinet with 4 steering rollers, 2 of them lock-type with brake.

Order No.: T9930-04

 

 

 

  • Technical Ventilation

If an evaporation of solvents cannot be avoided by procedural means, a technical ventilation is compulsory. The ventilation prevents the formation of a permanent explosive atmosphere (zone 0). Its efficiency is supervised redundantly by two flow switches. Depending on the density, the gases will be exhausted out of the unit either at ceiling level or at floor level. The air supply is effected vice-versa, at floor level or at ceiling level, to ensure, that the air flow covers all areas of the room. The fan ensures a high ventilation rate.

Order No.: T9980-01

 

  • Humidification

Equipped with the options humidification and dehumidification, an explosion-proof cold-heat test cabinet becomes an explosion-proof climatic test cabinet. Humidification of the Safety T-Line is effected by a specially controlled ultrasonic atomizer. Humidification of the Safety X-Line is realized by an explosion-proof version of evaporation humidification being installed in the test room. A plate heat-exchanger of stainless steel, which is optimized for this application, effects a dehumidification by falling below dewpoint. This combination of humidification and dehumidification allows a wide range
of temperature/humidity combinations. The sensor is a temperature-compensated, capacitive sensor, which can be calibrated.

 

 

 